In this vignette we show how to use the funcharts
package to apply the methods proposed in Capezza et al. (2020) to build
control charts for monitoring scalar quality characteristic adjusted for
by the effect of functional covariates, based on scalar-on-function
regression. Let us show how the funcharts
package works
through an example with the dataset air
, which has been
included from the R package FRegSigCom
and is used in the
paper of Qi and Luo (2019). The authors propose a function-on-function
regression model of the NO2
functional variable on all the
other functional variables available in the dataset. In order to show
how the package works, we consider a scalar-on-function regression
model, where we take the mean of NO2
at each observation as
the scalar response and all other functions as functional
covariates.
First of all, starting from the discrete data, let us build the
multivariate functional data objects of class mfd
, see
vignette("mfd")
.
library(funcharts)
data("air")
fun_covariates <- names(air)[names(air) != "NO2"]
mfdobj_x <- get_mfd_list(air[fun_covariates], grid = 1:24)
Then, we extract the scalar response variable, i.e. the mean of
NO2
at each observation:
In order to perform the statistical process monitoring analysis, we divide the data set into a phase I and a phase II dataset.
rows1 <- 1:300
rows2 <- 301:355
mfdobj_x1 <- mfdobj_x[rows1]
mfdobj_x2 <- mfdobj_x[rows2]
y1 <- y[rows1]
y2 <- y[rows2]
We can build a scalar-on-function linear regression model where the
response variable is a linear function of the multivariate functional
principal components scores. The principal components to retain in the
model can be selected with selection
argument. Three
alternatives are available (default is variance
):
tot_variance_explained
,single_min_variance_explained.
This criterion is used in
Capezza et al. (2020).Here, we use default values:
As a result you get a list with several arguments, among which the
original data used for model estimation, the result of applying
pca_mfd
on the multivariate functional covariates, the
estimated regression model. It is possible to plot the estimated
functional regression coefficients, which is also a multivariate
functional data object of class mfd
:
Moreover bootstrap can be used to obtain uncertainty quantification:
We can build the regression control chart to monitor the scalar
response, as performed in Capezza et al. (2020). The function
regr_cc_sof
provides a data frame with all the information
required to plot the desired control charts. Among the arguments, you
can pass the arguments y_tuning
and
mfdobj_x_tuning
set, that are not used for model
estimation/training, but only to estimate control chart limits. If these
arguments are not provided, control chart limits are calculated on the
basis of the training data. The arguments y_new
and
mfdobj_x_new
contain the phase II data set of observations
of the scalar response and the functional covariates to be monitored,
respectively. The function plot_control_charts
returns the
plot of the control charts.